Intermatic T103R 24-Hour Mechanical Time Switch 120 VAC DPST Indoor/Outdoor Metal Enclosure 1-Hour Interval

SKU
253183
More Information
Description The T100 Series Mechanical Time Switch has proven it can stand the test of time. These dependable time switches can handle electrical loads up to 40 A per pole and allow for up to 12 ON/OFF operations per day. A manual override switch provides added convenience.
Brand Name INTERMATIC
General Attributes

Features

  • Direct 24-hour control of most loads
  • Up to 12 ON/OFF operations each day with minimum ON/OFF times of one hour
  • Manual override
  • One ON and one OFF tripper included
  • Can be installed in most Intermatic enclosures

Compliance

  • CSA Certification File Number -> C22.2-177; LR3730

Prop 65

  • Please see the Warning @ www.P65Warnings.ca.gov - Lead

Specifications

  • Country of Origin: Mexico
  • Product Height: 10.125 in; 257.2 mm
  • Product Depth: 3.625 in; 92.1 mm
  • Operating Temperature Min: -40°F; -40°C
  • Operating Temperature Max: 130°F; 54°C
  • Warranty Period: 1-Year limited
  • Minimum On Off Time: 1 hour
  • Maximum On Off Operations: 12
  • Skipper Wheel Operation Mode: Not Included
  • Operation Mode: 24 hour
  • UL Cerfication File Number: UL917
  • Applications: Timing/Scheduling ON/OFF; Indoor Lighting Control; Outdoor Lighting Control
  • Application Compatibilities: LED; HID
  • Wire Size Min: #14 AWG
  • Wiring Option: Terminals
  • Input Voltage Ranges: 120 VAC 60 Hz
  • Wire Size Max: #8 AWG
  • Number Of Circuits: 1
  • Enclosure Type: Indoor/outdoor type 3R metal
  • Switch Type: DPST
  • Power Consumption Max W: 3 W
  • Pilot Duty Load Ratings Ranges: 1000 VA 120-240 VAC 60 Hz
  • Number Of Trippers Included: 1 ON/1 OFF
  • Has Manual Override CVL: Yes
  • PDF Standards And Certifications: cULus; cCSAus; LED

Certifications

  • UL Certification: cULus
  • CSA Certification: cCSAus
  • Other Certifications: LED

Load Ratings

  • Pilot Duty Load Ratings: 1000 VA 120-240 VAC 60 Hz
  • Electronic Ballast Load Ratings: 16 A 120 VAC; 16 A 208 VAC; 16 A 240 VAC; 16 A 277 VAC
  • Electronic Ballast Load Ratings Ranges: 16 A 120-277 VAC
  • Tungsten Load Ratings: 40 A 120 VAC 60 Hz; 40 A 208 VAC 60 Hz; 40 A 240 VAC 60 Hz
  • Tungsten Load Ratings Ranges: 40 A 120-240 VAC 60 Hz
  • Resistive Load Ratings: 40 A 240 VAC 60 Hz; 40 A 208 VAC 60 Hz; 40 A 120 VAC 60 Hz
  • Resistive Load Ratings Ranges: 40 A 120-240 VAC 60 Hz
  • Inductive Load Ratings: 40 A 240 VAC 60 Hz; 40 A 208 VAC 60 Hz; 40 A 120 VAC 60 Hz
  • Inductive Load Ratings Ranges: 40 A 120-240 VAC 60 Hz
  • Motor Load Ratings Ranges: 2 HP 24 FLA @ 120 VAC 60 Hz; 5 HP 28 FLA @ 240 VAC 60 Hz

Knockout

  • Knockout Dimensions Bottom: (2) combination 1/2" - 3/4"
  • Knockout Dimensions Back: (1) combination 1/2" - 3/4"

Downloads

Instruction Sheets
Spec Sheet

Videos

Weight 1.000000
UOM EA
UPC 07827502006
Weight 1.0000
Manufacturer Intermatic
Amperage Rating 40 A
Contact Form 2NO DPST
Dimensions 5-1/2 in L x 4 in W x 9-3/8 in
Enclosure Type NEMA 3R
Height 10.125 in
Horsepower 5 hp
Minimum Order Quantity 6/EA
Number of Circuits 1
Number of Poles 2
Series T100
Temperature Rating -40 to 130 deg F
Catalog Number T103R
Country of Origin MEX
Spec Sheet (1.14 MB)