6/3 With Ground (NM-B) Non-Metallic Romex Sheathed Cable 125 Ft. Coil

SKU
2129860
More Information
General Attributes

Downloads

Spec Sheet

Features

  • Color-coded inners for circuit identification
  • Available with and without ground
  • Rated for 90˚C in dry locations
  • Ampacity is limited to that for 60˚C conductors per NEC Article 334

Conductor

  • 14 AWG thou 10 AWG bare annealed Solid Copper per ASTM B3
  • 8 AWG and larger stranded bare annealed Copper per ASTM B8

Insulation

  • Premium-grade Polyvinyl Chloride (PVC) with a Nylon jacket
  • Color-coded: 2 conductor - Black White; 3 conductor - Black White Red

Grounding Conductor

  • Bare annealed Copper per ASTM B3 or ASTM B8

Assembly

  • Type THHN inners rated 90˚C in dry locations
  • 2-conductor - insulated conductors laid parallel with a Bare Copper grounding conductor wrapped in paper and laid parallel between the insulated conductors
  • 3-conductor - insulated conductors laid parallel or twisted together with Bare Copper grounding conductor wrapped in paper
  • The entire assembly is wrapped with a paper separator prior to applying the Polyvinyl Chloride (PVC) outer jacket

Outer Jacket

  • Polyvinyl Chloride (PVC)

Applications

  • Residential wiring as branch circuits for outlets switches and other loads
  • Exposed or concealed wiring
  • May be run through walls ceilings and masonry blocks
  • New wiring or replacement wiring
  • Only for use in normally dry locations

Compliances

  • UL Standard 83
  • UL Standard 719
  • ASTM B3 and B8
  • NEC Article 334
  • Federal Specification A-A-59544

Packaging

  • 250' or 125' coils or 1000' reels

Specifications

  • Number of Wires: 7
  • Insulation Thickness (in): 0.03
  • Insulation Thickness (mm): 0.76
  • Insulation Color: Black
  • Jacket Thickness (in): 0.005
  • Jacket Thickness (mm): 0.13
  • Nominal Cable O.D. (in): 0.612
  • Nominal Cable O.D. (mm): 15.54
  • Copper Weight (lbs/1000 FT): 277
  • Copper Weight (kg/km): 412
  • Total Weight (lbs/1000 FT): 352
  • Total Weight (kg/km): 524
  • Ampacity: 55
  • Stranding: Stranded
  • Material: Copper With Ground
  • Size: 6 AWG - 3 Conductor
  • Length: 125'
  • Conductor Material: Copper
  • Insulation Material: PVC
  • Wet Location Use: No
  • Direct Burial: No
  • Grounded: Yes
  • Voltage Rating: 600 V
Weight 0.274000
UOM FT
UPC 2129860
Manufacturer Wire
Color Black
Material Copper With Ground
Amperage Rating 55 A
Material Copper With Ground
Length 125 ft
Number of Conductors 4
Wire Size 6 AWG
Spec Sheet (196.36 kB)
Spec Sheet (196.90 kB)